Technical Specifications

Gigabit Multimode Fibre Tap Specs:

Max Distance: 220 meters @ 62.5/125μm, 850nm wavelength / 550 meters @ 50/125 μm, 850 wavelength
Split Ratio Network Port IL Monitor Port IL Network Distance62.5/125μm 50 Micron Distance

50/50 < 4.5 dB < 4.5 dB 1‐44 meters 1‐110 meters
60/40 < 3.1 dB < 5.1 dB 44‐88 meters 110‐220 meters
70/30 < 2.4 dB < 6.3 dB 88‐132 meters 220‐330 meters
80/20 < 1.8 dB < 8.1 dB 132‐176 meters 330‐440 meters
90/10 < 1.3 dB < 11.5 dB 176‐220 meters 440‐550 meters

Gigabit Single mode Fibre Tap Specs:

Max Distance: 5 Km, 8.5/125μm, 1310nm wavelength
Split Ratio Network Port IL Monitor Port IL Network Distance
50/50 < 3.7 dB < 3.7 dB 0‐1 Km
60/40 < 2.8 dB < 4.8 dB 1‐2 Km
70/30 < 2.0 dB < 6.1 dB 2‐3 Km
80/20 < 1.3 dB < 8.0 dB 3‐4 Km
90/10 < 0.8 dB < 12.0 dB 4‐5 Km

Indicated Maximum Monitoring Cable Distance for All Optical:
Split Ratio Multimode 62.5/125μm Multimode 50/125μm Singlemode 8.5/125μm


50/50 1‐44 meters 1‐110 meters 0‐1 Km
60/40 1‐28 meters 1‐ 75 meters 0‐750 meters
70/30 1‐23 meters 1‐ 58 meters 0‐540 meters
80/20 1‐17 meters 1‐ 44 meters 0‐350 meters
90/10 1‐12 meters 1‐ 31 meters 0‐210 meters

Indicated Maximum Monitoring Cable Distance for 100/1000Mb: 1‐80 meters
(These figures are guidelines only. The monitoring cable distance may vary between installations )